REVERE CO₂ Water to Water Heat Pump
- Boiler and water chiller all in one machine
- Efficiently generate high quality hot water
- Cut energy costs by reducing or eliminating traditional water heating equipment
- Reclaim waste energy or other renewable heat sources
- Cut energy costs & reduce CO2 footprint
- No combustion, safe to run and no NOx.
- Natural refrigerant CO2 (ODP=0, GWP=1)
- 70 – 100kW heating capacity (up to 90°C hot water)
- 70 – 80kW cooling capacity (down to -9°C chilled water)
- 25kW motor (combined COP <8.0)
Revere™ CO2 Water to Water Heat Pump is an industrial/commercial heat pump system that generates hot water and chilled water or hot water by recovering energy from renewable and waste heat sources such as waste water from process, cooling water from conventional cooling tower or ground water/geothermal heat. It uses CO2 (a natural refrigerant) instead of chemical refrigerants such as HCFC/HFC typically used in other heat pump systems.
- Performs the functions both of Boiler and Water Chiller all in one machine
Both 65º hot water and 7º chilled water can be supplied simultaneously.
Effective Utilization of Unused Waste HeatUnused low temperature waste heat from the plant or cooling water can be used as heat source.
Compact DesignEasy installation due to a 10% reduction in size.
Reduction of Existing Water Chiller Power ConsumptionPerformance of existing water chiller is increased and also its power consumption is decreased by utilizing its chilled water as a heat source.
Equalization of Electricity Power LoadStoring hot water and chilled water using off peak tariff of electricity, the peak cut of electricity demand can be achieved
-
-
Model AHGWW-HTC Power 3-phase 415V AC 50Hz/60Hz Water Heat Source Brine1 Chilled Water2 Chilled Water3 Heat Recovering4 Temperature In / Out (ºC) -5 / -9 12 / 7 15 / 10 37 / 32 Water (ºC) 17 17 17 17 Capacity
(Hot Water Supply
65ºC)Heating (kW) 53.2 85.8 91.9 116.8 Cooling (kW) 37.9 64 69.5 94.8 Power Consumption (kW) 18.4 22.1 22.4 22.7 Outer Dimensions (mm) W1,100 × L1,200 × H1,893 Weight (kg) 985 (Net), 1,007 (Operating) Compressor Motor 25kW x 4P Star-up Method Inverter External Connection Water Inlet Rc3/4 (20A tap female, SUS316) Hot Water Outlet Rc3/4 (20A tap female, SUS316) Chilled Water Inlet Rc2 (50A tap female, SUS316) Chilled Water Outlet Rc2 (50A tap female, SUS316) Heat Exchanger Hot Water Chilled Water Operating Ranges Fluid Water Water / Brine Inlet Temp. (ºC) 5 to 65 -5 to 37 Outlet Temp. (ºC) 65 or 90 -9 to 32 Flow Rate (L/min) 5 to 35 100 to 284 Water Pressure (MPa) 0.25 to 0.5 0.1 to 1.0 Ambient Temp. (ºC) -10 ~ 43 Colour Enclosure / Base Munsell N8.0 approximate color / Munsell N1.0 approximate color Noise (dBA) kg 57 Note: Please install an approval pressure limiting valve if the inlet water pressure is to exceed the values.
Model
AHGWW-HTCPower 3-phase 415V AC 50Hz/60Hz Water Heat Source Brine1 Chilled Water2 Chilled Water3 Heat Recovering4 Temperature In / Out (ºC) -5 / -9 12 / 7 15 / 10 37 / 32 Water (ºC) 17 17 17 17 Capacity
(Hot Water Supply
65ºC)Heating (kW) 53.2 85.8 91.9 116.8 Cooling (kW) 37.9 64 69.5 94.8 Power Consumption (kW) 18.4 22.1 22.4 22.7 Outer Dimensions (mm) W1,100 × L1,200 × H1,893 Weight (kg) 985 (Net), 1,007 (Operating) Compressor Motor 25kW x 4P Star-up Method Inverter External Connection Water Inlet Rc3/4 (20A tap female, SUS316) Hot Water Outlet Rc3/4 (20A tap female, SUS316) Chilled Water Inlet Rc2 (50A tap female, SUS316) Chilled Water Outlet Rc2 (50A tap female, SUS316) Heat Exchanger Hot Water Chilled Water Operating Ranges Fluid Water Water / Brine Inlet Temp. (ºC) 5 to 65 -5 to 37 Outlet Temp. (ºC) 65 or 90 -9 to 32 Flow Rate (L/min) 5 to 35 100 to 284 Water Pressure (MPa) 0.25 to 0.5 0.1 to 1.0 Ambient Temp. (ºC) -10 ~ 43 Colour Enclosure / Base Munsell N8.0 approximate color / Munsell N1.0 approximate color Noise (dBA) kg 57 Note: Please install an approval pressure limiting valve if the inlet water pressure is to exceed the values.
-